logo
×

Solar Inverter Data Logger TF Memory Card 64GB 128GB 256GB U3 V30 Class 10

Product Specification
Place of Origin: Shenzhen, China
Brand Name: PG
Certification: CE, RoHS, FCC
Model Number: S25128TLIA
Minimum Order Quantity: 50 Pieces
Price: Negotiable
standard packaging: Anti-static bag plus retail blister box, export grade carton, customizable
Delivery Time: 10 to 15 days
Payment Terms: L/C,T/T
Supply Ability: 100K per month

Product Summary

Solar inverter data logger TF memory card, -25C to 85C, 64GB to 256GB, U3 V30 Class 10 for on site plant history.

Product Details

Highlight:

Solar Inverter Data Logging

,

Wide Temperature Outdoor Operation

,

U3 V30 Sustained Write Speed

Application: Solar Inverter Data Logger
Operating Temperature: -25C To 85C
Storage Temperature: -40C To 85C
Capacity: 64GB / 128GB / 256GB
Interface: SD6.1 UHS-I
Sustained Write: Up To 50MB/s
Endurance: 3,000 P/E Cycles
Data Retention: 10 Years At 25C
File System: ExFAT
Product Name: Solar Inverter Data Logger TF Memory Card

Product Description

Solar Inverter Data Logger TF Memory Card 64GB 128GB 256GB U3 V30

A solar plant lives on its history. Every five minutes the inverter writes string voltage, DC input current, AC output power, cabinet temperature and fault codes to local storage, and that history is what a service team reads months later to explain a yield drop. When the local copy is missing, the only evidence left is the cloud feed, which depends on a network link that may have been down for the exact period under review. A solar inverter data logger TF memory card keeps that primary record on site, independent of connectivity.

The environment is the difficulty. An inverter cabinet on a rooftop or in a desert array can pass 70C internally in summer and fall below -10C on a winter night, and the logger keeps writing through both. A solar inverter data logger TF memory card rated for the extended -25C to 85C window holds its write margin across that cycle, which matters because a logger does not stop when the card becomes unreliable; it simply writes fewer records than the operator assumes.

This card is supplied in 64GB, 128GB and 256GB on the SD6.1 UHS-I interface and is formatted exFAT. U3 and V30 sustain the write throughput a multi-inverter gateway needs when it aggregates several streams into one log, while LDPC error correction keeps the folder structure intact when a cabinet is powered down for maintenance without a clean shutdown. Many monitoring gateways keep a year of five minute data in text form, so 64GB is often sufficient; sites that store waveform captures or inverter event dumps move to 128GB or 256GB.

Verification follows the same route as the rest of this industrial family: thermal chamber cycling across the rated window, sustained write testing at the rated class, and capacity verification before packing. Test records are filed per production lot so an EPC contractor can attach them to a commissioning dossier rather than relying on a datasheet claim.

This page covers one part family rather than one model. The same solar inverter data logger TF memory card is supplied in three capacities, and projects that already run a solar inverter data logger TF memory card from another vendor usually compare the operating window, the sustained write class and the endurance figure before switching. Those three figures decide whether a plant can standardise on one solar inverter data logger TF memory card as the site spare.



Technical Specifications
Interface SD6.1, UHS-I
Capacity 64GB / 128GB / 256GB
Speed Class C10, U3, V30, A2, A1
Sustained Write Up to 150MB/s
Sequential Read Up to 180MB/s
Endurance 3,000 program / erase cycles 
Data Retention 10 years at 25C
Operating Temperature -25C to 85C
Storage Temperature -40C to 85C
Error Correction Advanced ECC with LDPC
File System exFAT


Solar Inverter Data Logger TF Memory Card 64GB 128GB 256GB U3 V30 Class 10

Solar Inverter Data Logger TF Memory Card 64GB 128GB 256GB U3 V30 Class 10


Solar Inverter Data Logger TF Memory Card 64GB 128GB 256GB U3 V30 Class 10

Typical Installations

Rooftop and ground mount string inverters with an on-board logging slot.

Central inverter cabinets in utility scale arrays.

Energy meter gateways aggregating several inverters into one log.

Weather station and irradiance sensor nodes on the same site bus.

Off-grid and hybrid systems where no backhaul link is available.

Battery storage cabinets recording charge and discharge cycles.

Design Advantages

Extended -25C to 85C operating window suits sealed outdoor cabinets.

U3 and V30 classes sustain write throughput during multi-inverter aggregation.

LDPC correction preserves the log after an unclean shutdown for service work.

exFAT supports large log folders without split volume workarounds.

One capacity family from 64GB to 256GB simplifies spare parts stocking.

Lot traceability and thermal test records support commissioning documentation.

Questions From Project Teams
Why keep a local card when the site already reports to a cloud platform?
Because the cloud path depends on a modem, a router and a subscription. When that chain breaks, the local solar inverter data logger TF memory card is the only record of what the array did during the outage, and it is the file a warranty discussion usually turns on.
Will the card survive a hot inverter cabinet in summer?
The rated operating window reaches 85C, which covers the internal temperature of most sealed cabinets in strong sun. Where a cabinet runs hotter than that, the correct fix is airflow or a remote logging enclosure, and our engineers will say so rather than quote a card that cannot meet the condition.
How much history fits on each capacity?
Five minute text records with a few dozen parameters are small, so 64GB typically holds several years for a single inverter. Waveform captures, event dumps and multi-inverter aggregation consume space quickly, and those projects usually specify 128GB or 256GB.
What happens if the cabinet is switched off without a shutdown command?
The card relies on firmware level error correction and LDPC to keep the file system mountable after an interrupted write. On restart the gateway can mount the volume and continue logging, though the record covering the interruption itself may be lost, which is normal for removable media.
Can the test data be used in a commissioning file?
Yes. Thermal cycling between -25C and 85C, sustained write results and capacity verification are recorded per lot, and the report can be issued with the matching lot number for the delivery.
PG supplies industrial memory products from Shenzhen with CE, RoHS and FCC certified production. Thermal cycling and endurance reports are issued per production lot on request.
Overall Rating
5.0
Based on 50 reviews recently
Rating Snapshot
5
100%
4
0
3
0
2
0
1
0
All Reviews
T
T*J from France
Jun 22.2026
amazing product, highly recommended
Y
Y*i from South Korea
May 13.2026
The quality was perfect. The delivery service was on time as well.
T
T*i from Netherlands
Apr 2.2026
This supplier offers custom logo service. Our brand logo was printed excellently on the cards. The printing is super clear and high resolution.
You May Also Like